Meters & Instruments
C4002561
Hard Case For LoadLooker Ammeter: Fits one of the following, MEAMP11RW, MEAMP21RW, MEAMP32RN, or MEAMP32RN2
C4033178
Wet / Dry Hot Stick Tester, 115V: For testing any length fiberglass-reinforced plastic (FRP) hot stick up to 3 inches in diameter, the Wet/Dry Tester offers convenience for spot checks at field jobsites or periodic diagnostics in the workshop. It’s like having full-scale test setups for both Wet 75kV-perfoot and Dry 100kV-per-foot in a compact, self-contained unit easily carried and operated by just one person. In the Setup procedure before each use, a zeroing knob is used to set the meter to zero without a tool in the tester. Then the furnished Check Bar is used as a self-check to make sure the tester is functional
C4002560
Soft Case For LoadLooker Ammeter: Fits one of the following, MEAMP11RW, MEAMP21RW, MEAMP32RN, or MEAMP32RN1
MEAMP32RN2
LoadLooker Ammeter, Up to 500kV, 50 Hertz Unit: U-shape jaw senses the amperage present between tines, narrow jaw for up to 5000 Amps. The open-end design lets you check loads on components not accessible by other hot-line ammeters. It features a Universal fitting that mounts on insulated hotsticks, a single button operation. The HOLD feature lets you bring down single reading to eye level. Auto shut off after five minutes idle, or manually turn off by depressing button for five seconds
MEAMP32RN
LoadLooker Ammeter, Up to 500kV, 60 Hertz Unit: U-shape jaw senses the amperage present between tines, narrow jaw for up to 5000 Amps. The open-end design lets you check loads on components not accessible by other hot-line ammeters. It features a Universal fitting that mounts on insulated hotsticks, a single button operation. The HOLD feature lets you bring down single reading to eye level. Auto shut off after five minutes idle, or manually turn off by depressing button for five seconds
MEAMP21RW
LoadLooker Ammeter, Up to 400kV, 60 Hertz Unit: U-shape jaw senses the amperage present between tines, wide jaw for up to 2000 Amps.The open-end design lets you check loads on components not accessible by other hot-line ammeters. It features a Universal fitting that mounts on insulated hotsticks, a single button operation. The HOLD feature lets you bring down single reading to eye level. Auto shut off after five minutes idle, or manually turn off by depressing button for five seconds
MEAMP11RW
LoadLooker Ammeter, Up to 69kV, 60 Hertz Unit: U-shape jaw senses the amperage present between tines, wide jaw for up to 2000 Amps.The open-end design lets you check loads on components not accessible by other hot-line ammeters. It features a Universal fitting that mounts on insulated hotsticks, a single button operation. The HOLD feature lets you bring down single reading to eye level. Auto shut off after five minutes idle, or manually turn off by depressing button for five seconds
PST6003541
Bus Bar Clamp Adapter: Allows for the testing of bus bar clamps with CHANCE Ground Set Tester (C4033220)
PSC4033796
Protective Grounding Set Tester Elbow Adapter, 35kV: For .75″ Probe and testing special-application grounding sets
PSC4032947
Protective Grounding Set Tester Elbow Adapter, 35kV: For .50″ Probe and testing special-application grounding sets
C4033449
Protective Grounding Set Tester Elbow Adapter, 15kV & 25kV: For .50″ Probe and testing special-application grounding sets
T4033159
Protective Grounding Set Tester Straight Stud Terminal: For testing special-application grounding sets
PSC4033220003
Protective Grounding Set Tester, 230V: Self-contained, portable convenient 230 VAC tester provides an easy way for an electric utility to check the resistance in protective grounding sets used by line personnel.
C4033220
Protective Grounding Set Tester, 115/120V: Self-contained, portable, convenient 120 VAC tester provides an easy way for an electric utility to check the resistance in protective grounding sets used by line personnel.
C4030803
Energized Cable Sensor: For indicating whether or not a URD cable is energized. Kit includes URD Cable Sensor, two leads, two 9-volt batteries, and instructions.
PSC4033679
Polymer Insulator Tester for transmission suspension insulators 69kV though 500kV. The kit includes a Tester, Battery charger, Adapter cables, Calibration samples, Holder and Users Manual.
C4032299
Energized Transmission Insulator Tester, (44kV – 500kV): Mounted on a 1.25″-diameter Epoxiglas® pole with a universal fitting, before each use the tester should be attached to the proper length hot stick for the system voltage involved. The scale reads up to 16 kV. Applications Without interrupting service, one of these testers quickly can check the condition of each insulator in a string. This greatly reduces maintenance costs. Rather than changing out entire strings, only the insulators identified as damaged require replacements. The testers serve specific applications for suspension insulators on 44 kV through 500 kV transmission systems.
C4032298
Energized Distribution Insulator Tester, (through 35kV): Mounted on a 1.25″-diameter Epoxiglas® pole with a universal fitting, before each use the tester should be attached to the proper length hot stick for the system voltage involved. The scale reads up to 11 kV. Applications Without interrupting service, one of these testers quickly can check the condition of each insulator in a string. This greatly reduces maintenance costs. Rather than changing out entire strings, only the insulators identified as damaged require replacements. The testers serve specific applications for deadend insulators on distribution systems through 35 kV.
Ready To Order?
© 2024 Brenco Power Line Tools